Factory Cheap Low Fin Tube - ASTM A179 U Bend Heat Exchangers Tube – Datang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our commission is to serve our buyers and purchasers with most effective good quality and aggressive portable digital goods for Copper Condenser , Natasha Finned Tubes , Copper Tube Spiral , On account of superior excellent and aggressive rate , we will be the sector leader, make sure you don’t hesitate to contact us by cellular phone or email, if you're fascinated in almost any of our items.
Factory Cheap Low Fin Tube - ASTM A179 U Bend Heat Exchangers Tube – Datang Detail:

● ASTM A179/ ASME SA179;

● ASTM A213/ ASME SA 213, T11, T22, T22, T5;

● ASTM A213/ ASME SA213, TP304/304L, TP316/316L, S31803, S32205, S32750, S32760, TP410;

● ASTM B111, C44300, C68700, C70600, C71500;

● ASTM B338, GR.1, GR.2.

● Monel Alloys.

● Nickel Alloys.

● U Bend Dimension capability.

● Tube OD.: 12.7mm-38.1mm.

● Tube Thickness: 1.25mm-6mm.

● Bending Radius: Min.1.5 x OD/ Max. 1250mm.

● U tube Straight “leg” Length: Max. 12500mm.

● Straight tube before U bending: Max. 27000mm.

U Bend Tubes for Heat Exchangers applied mostly in oil & gas plants, chemical & petrochemical plants, refineries, power plants, renewable energy plants.

1. Heat Treatment and Solution Annealing / Bright Annealing

2. Cutting to required length and deburring

3. Chemical Composition Analysis Test With 100% PMI and One tube from each heat by Direct Reading Spectrometer

4. Visual Test and Endoscope Test for Surface Quality Test

5. 100% Hydrostatic Test/Pneumatic test and 100% Eddy Current Test

6. Ultrasonic Test subject to the MPS (Material Purchase Specification)

7. Mechanical Tests includes Tension Test, Flattening Test, Flaring Test, Hardness Test

8. Impact Test subject to Standard request

9. Grain Size Test and Intergranular Corrosion Test

10. Ultrasoic measuring of Wall Thickness

11. Stress Relieve Annealing on U bend Parts after bending

2240900248

‘U’ Bend Stainless Steel Tubes are manufactured in our plant as per the customer requirements. Bends can be Heat Treated in accordance with Clients’ requirements followed by hydrostatic testing and dye penetrant testing if required.

U bent tubes are widely used in heat-exchanger systems. Heat exchanger equipment on the basis of stainless U-tube is essential in strategically important and critical fields nuclear and petrochemical machine building.

U-tube heat exchangers Designed for high temperature applications, especially steam condensing or hot oil systems. Thïs model is selected when differential expansion makes a fixed tube sheet exchanger unsuitable and when conditions preclude a floating head type (HPF) selection.

Surface condition Finished U-tubes shall be free of scale, without scratches after bending.

1. High-pressure hydrostatic test: minimum: 10 Mpa-25Mpa.

2. Underwater air test after bending

3. U-tube wall thickness test

4. Eddy current test before U-shaped bend is formed

5. Ultrasonic test before U-shaped bend is formed

6. Heat treatment can relieve stress

A. Cut all the pipes to the specified leg length, and use air for internal cleaning and deburring.

B. Before packaging, both ends of the U-shaped elbow are covered with plastic covers.

C. Vertical separator for each radius.

D. Each plywood box is equipped with a packing list covered with plastic to facilitate identification of order details, including an accurate list of internal radius and length.

U Bend Stainless Steel Heat Exchanger Tube, U Bent Pipe

U bend pipe for boiler and superheater

With strong wood structure box packing by containers loading and shipping.

Heater tubes U TUBES with Stainless, Alloy steel grade available, Carbon Steel grade is also available.

Size Range for tubing: OD:1/4″ (6.25mm) to 8″ (203mm), WT 0.02″ (0.5mm) to 0.5″(12mm).

Length: 30 m(Max) or as your requirement.

Process: Cold drawn, Cold rolled, Precision Rolled for Seamless Pipe or Tube.

Finish: Annealed & pickled, bright annealing, polished.

Ends: Beveled or plain end, square cut, burr free ,Plastic Cap at Both end.

Applications: Heater, Heat Exchanger,  Condencer, Machining, Bearing Machining, API Service.


Product detail pictures:

Factory Cheap Low Fin Tube - ASTM A179 U Bend Heat Exchangers Tube  – Datang detail pictures


Related Product Guide:

Generally customer-oriented, and it's our ultimate goal for being not only the most trusted, trustable and honest provider, but also the partner for our customers for Factory Cheap Low Fin Tube - ASTM A179 U Bend Heat Exchangers Tube – Datang , The product will supply to all over the world, such as: Marseille, United States, Georgia, We confirm to public, cooperation, win-win situation as our principle, adhere to the philosophy of make a living by quality, keep developing by honesty , sincerely hope to build up a good relationship with more and more customers and friends, to achieve a win-win situation and common prosperity.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Susan from Eindhoven - 2018.07.27 12:26
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Kama from Stuttgart - 2017.02.28 14:19
    Write your message here and send it to us