Factory Outlets Flue Gas Cooler - ASTM A179 U Bend Heat Exchangers Tube – Datang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been convinced that with joint attempts, the business enterprise between us will bring us mutual benefits. We could guarantee you product or service good quality and aggressive value for Architectural Finned Tube , Propane Heat Exchanger , Steam Fin Tube , We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.
Factory Outlets Flue Gas Cooler - ASTM A179 U Bend Heat Exchangers Tube – Datang Detail:

● ASTM A179/ ASME SA179;

● ASTM A213/ ASME SA 213, T11, T22, T22, T5;

● ASTM A213/ ASME SA213, TP304/304L, TP316/316L, S31803, S32205, S32750, S32760, TP410;

● ASTM B111, C44300, C68700, C70600, C71500;

● ASTM B338, GR.1, GR.2.

● Monel Alloys.

● Nickel Alloys.

● U Bend Dimension capability.

● Tube OD.: 12.7mm-38.1mm.

● Tube Thickness: 1.25mm-6mm.

● Bending Radius: Min.1.5 x OD/ Max. 1250mm.

● U tube Straight “leg” Length: Max. 12500mm.

● Straight tube before U bending: Max. 27000mm.

U Bend Tubes for Heat Exchangers applied mostly in oil & gas plants, chemical & petrochemical plants, refineries, power plants, renewable energy plants.

1. Heat Treatment and Solution Annealing / Bright Annealing

2. Cutting to required length and deburring

3. Chemical Composition Analysis Test With 100% PMI and One tube from each heat by Direct Reading Spectrometer

4. Visual Test and Endoscope Test for Surface Quality Test

5. 100% Hydrostatic Test/Pneumatic test and 100% Eddy Current Test

6. Ultrasonic Test subject to the MPS (Material Purchase Specification)

7. Mechanical Tests includes Tension Test, Flattening Test, Flaring Test, Hardness Test

8. Impact Test subject to Standard request

9. Grain Size Test and Intergranular Corrosion Test

10. Ultrasoic measuring of Wall Thickness

11. Stress Relieve Annealing on U bend Parts after bending

2240900248

‘U’ Bend Stainless Steel Tubes are manufactured in our plant as per the customer requirements. Bends can be Heat Treated in accordance with Clients’ requirements followed by hydrostatic testing and dye penetrant testing if required.

U bent tubes are widely used in heat-exchanger systems. Heat exchanger equipment on the basis of stainless U-tube is essential in strategically important and critical fields nuclear and petrochemical machine building.

U-tube heat exchangers Designed for high temperature applications, especially steam condensing or hot oil systems. Thïs model is selected when differential expansion makes a fixed tube sheet exchanger unsuitable and when conditions preclude a floating head type (HPF) selection.

Surface condition Finished U-tubes shall be free of scale, without scratches after bending.

1. High-pressure hydrostatic test: minimum: 10 Mpa-25Mpa.

2. Underwater air test after bending

3. U-tube wall thickness test

4. Eddy current test before U-shaped bend is formed

5. Ultrasonic test before U-shaped bend is formed

6. Heat treatment can relieve stress

A. Cut all the pipes to the specified leg length, and use air for internal cleaning and deburring.

B. Before packaging, both ends of the U-shaped elbow are covered with plastic covers.

C. Vertical separator for each radius.

D. Each plywood box is equipped with a packing list covered with plastic to facilitate identification of order details, including an accurate list of internal radius and length.

U Bend Stainless Steel Heat Exchanger Tube, U Bent Pipe

U bend pipe for boiler and superheater

With strong wood structure box packing by containers loading and shipping.

Heater tubes U TUBES with Stainless, Alloy steel grade available, Carbon Steel grade is also available.

Size Range for tubing: OD:1/4″ (6.25mm) to 8″ (203mm), WT 0.02″ (0.5mm) to 0.5″(12mm).

Length: 30 m(Max) or as your requirement.

Process: Cold drawn, Cold rolled, Precision Rolled for Seamless Pipe or Tube.

Finish: Annealed & pickled, bright annealing, polished.

Ends: Beveled or plain end, square cut, burr free ,Plastic Cap at Both end.

Applications: Heater, Heat Exchanger,  Condencer, Machining, Bearing Machining, API Service.


Product detail pictures:

Factory Outlets Flue Gas Cooler - ASTM A179 U Bend Heat Exchangers Tube  – Datang detail pictures


Related Product Guide:

We have now a skilled, performance group to offer excellent support for our consumer. We usually follow the tenet of customer-oriented, details-focused for Factory Outlets Flue Gas Cooler - ASTM A179 U Bend Heat Exchangers Tube – Datang , The product will supply to all over the world, such as: Jersey, Jordan, Boston, Our products are very popular in the word, like South American, Africa, Asia and so on. Companies to "create first-class products" as the goal, and strive to provide customers with high quality products, provide high-quality after-sales service and technical support, and customer mutual benefit, create a better career and future!
  • The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Laurel from Turin - 2017.10.27 12:12
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Pearl from San Francisco - 2017.07.28 15:46
    Write your message here and send it to us